Kenmore 795 Bottom-Freezer Refrigerator Code F dH / r dH: Defrost Did Not Warm Up
Kenmore bottom-freezer refrigerators with model numbers starting 795 are an LG-built platform. On them, F dH or r dH tells you the defrost sensor never rose above 40 degrees F during a defrost cycle. That points…
- Code
- F dH / r dH
- Appliance
- Refrigerator
- Brand
- Kenmore
- Warranty
- 30-day workmanship
What F dH / r dH means
Kenmore bottom-freezer refrigerators with model numbers starting 795 are an LG-built platform. On them, F dH or r dH tells you the defrost sensor never rose above 40 degrees F during a defrost cycle. That points at the defrost circuit, meaning the sensor, a fuse, the heater or the control board. You may see frost building on the back panel and temperatures drifting upward in the compartment.
Common causes of F dH / r dH
- Defrost fuse that is open
- Defrost heater not warming the evaporator
- Defrost sensor or its wiring
- Control board output for the defrost circuit
1. Note whether F dH or r dH is showing, because it tells us which compartment the defrost belongs to. 2. Move perishable food to a cooler if the freezer feels warm. 3. Make sure nothing blocks the interior air vents. 4. Do not chip frost from the evaporator cover. Leave the panels alone and call us.
- Which of the four defrost parts has stopped the warm-up
- We check the sensor and its wiring first, then the fuse and heater, and the board last
- Heavy frost already on the evaporator can mask the original cause until it is thawed
Other Refrigerator codes
What is the 40 degree F figure?
During defrost the sensor is expected to pass 40 degrees F. When it never gets there, the control flags F dH or r dH, and we then check the sensor, fuse, heater and board in that order.
Does the letter F or r matter?
Yes. F relates to the freezer defrost and r to the refrigerator side, so we start in the matching area and bring the right sensor and heater to the visit instead of opening both sections blindly.
Can I just wait it out?
Frost keeps building while defrost is not working, so cooling gets worse over days and food is at risk. Early service keeps the repair smaller, because a thick frost layer takes time to melt before we can test.
Still seeing F dH / r dH?
A technician diagnoses it on site and gives you the price in writing before any work starts.